GutterMelt

Gutters - Downspouts - Eaves
Snow And Ice Melting Products

Heatizon Systems Gutter Melt
 
   
Heatizon Systems GutterMelt rain gutter, downspout, and eave deicing products provides heat to control ice dam formation and to maintain flow paths on eaves, and in gutters and downspouts. This heating cable is placed directly on top of the shingles or roofing material and/or in the rain gutter and downspout system. Snow and ice removal can be activated by a simple switch, or made even more simple by adding an automatic temperature moisture sensor.
Fast and Easy Installation

Heatizon Systems GutterMelt utilizes easy to install self-regulating or MI heating cable to provide reliable freeze protection of roofs, gutters, downspouts and roof drains. Simply run the cable in gutters using Heatizon Foil Tape (Heatizon Part No. HT40999) with pressure sensitive adhesive to secure cable placement. The cable can also be inserted in downspouts using downspout hangers to support the heating cable. Roof clips attach the cable to standard roofing material for eave melt. Self regulating GutterMelt can be cut to length in the field, while GutterMelt MI Cable is custom ordered to make installation convenient and easy.  

GutterMelt Self Regualting Eave Deicing Roof
Energy Efficient and Cost Effective
Heatizon Systems self-regulating GutterMelt system automatically adjusts to the appropriate heat output as ambient conditions change. When precipitation is expected, simply energize the cable. The cable provides maximum melting power when snow or ice is present, but will automatically regulate its output and save energy when the roof and gutters are clear of snow and ice. The other Option? Heatizon Systems MI GutterMelt system comes in fixed lengths and looks like copper tubing. Like self-regulating GutterMelt, MI Gutter Melt Cable is 100% efficient and can be activated a variety of different ways.
Value

Snow and ice causes millions of dollars of damage to roofs, gutters, and downspouts every year. As winter progresses through cycles of freezing and thawing, buildings experience ice buildup which can lead to roof damage, or damage caused by snow and ice falling from the roof. These cycles can cause ice to accumulate and back up under shingles. Resulting in ice dams. In some cases, damage appears in the form of soaked insulation, stained, cracked and damaged sheet rock, damp, smelly, rotting wall cavities and stained, blistered and peeling paint. Heatizon Systems has the products and expertise to effectively solve potential winter issues and protect your investment by controlling ice dams, managing icicles, and keeping ice from accumulating in gutters and downspouts.
Safety   Specifications

The Heatizon GutterMelt System is UL Listed and CSA Certified. Additionally, gutters and downspouts should be kept clear of leaves and other debris to ensure safe and efficient operation.

 
Buss Wire
Copper
Ground Braid
Tinned copper braid under jacket or copper tube
Outer Jacket
U.V. stabilized weatherproof jacket or copper tube
Environmental Use
Use only in ordinary areas
Maximum Exposure Temperature
149 ° F (65°C)
Output Wattage
5 to 12 watts/Foot in snow or ice at 32 ° F
Service Voltage
Operates on 120 VAC, 208-277 VAC, 480 VAC

 

GutterMelt SR Performance Ratings GutterMelt SR Power Output Curve
Copper bus wire 16 AWG
Nominal Power Output 5, 9, or 12 Watts/Ft in iced water at 32ºF (0ºC)
Max Maintenance Temperature 149ºF (65ºC)
Max intermittent exposure temperature 212ºF (100ºC)
T rating: T5
Voltage 120, 208, 240, 277
or 480 VAC
Watts at 32°F (0°C) Up to 12W per lin. ft.
Length Refer to product label
Diameter/Height Approx. 0.22” x 0.42”
Bending Radius Not tighter than 2” inside diameter
Minimum Spacing 2”
Cap Thickness None Required
GutterMelt Output Curve
   
GutterMelt SR Breaker Sizing and Max Circuit Length
Click Here to use our GutterMelt Length Calculator
 
GutterMelt 5 W/ft
120V
240V
Breaker Size
Startup@40°F
Startup@0°F
Startup@-20°F
15A
300 ft
200 ft
180 ft
20A
--
270 ft
230 ft
30A
--
330 ft
330 ft
40A
--
--
--
15A
660 ft
410 ft
360 ft
20A
--
560 ft
480 ft
30A
--
660 ft
660 ft
40A
--
--
--
 
 
GutterMelt 9 W/ft
120V
240V
Breaker Size
Startup@40°F
Startup@0°F
Startup@-20°F
15A
150 ft
95 ft
85 ft
20A
200 ft
125 ft
100 ft
30A
210 ft
190 ft
170 ft
30A
210 ft
190 ft
170 ft
15A
295 ft
195 ft
170 ft
20A
390 ft
250 ft
225 ft
30A
420ft
375 ft
340 ft
40A
--
420 ft
420 ft
 
 
GutterMelt 12 W/ft
120V
240V
Breaker Size
Startup@40°F
Startup@0°F
Startup@-20°F
15A
115 ft
70 ft
60 ft
20A
150 ft
95 ft
85 ft
30A
180 ft
145 ft
120 ft
40A
--
180 ft
165 ft
15A
230 ft
150 ft
130 ft
20A
305 ft
200 ft
175 ft
30A
360 ft
300 ft
260 ft
40A
--
360 ft
360 ft
 
   
Installation Accessories Features Solutions
  • Power Connection Kit
  • End Seal Kit
  • Roof Clips
  • Downspout Hangers
  • Aluminum Tape
  • Easy to Install
  • Cut to Length
  • Listed to UL Standards
  • CSA Certified
  • GutterMelt SR Approx. 3/4" W x 1/4" H
  • GutterMelt MI Approx 1/4" Diameter
  • Controls ice dams and minimizes icicles
  • Provides a path for water to escape the roof
  • Reduces snow and ice build up
  • Minimizes snow slides
  • Commercial, industrial and residential buildings
Customer Service  
Our highly experienced Distributor and Technical Support Teams are the best in the business. We also manufacture a family of under-roof snow melt and deicing products, driveway snow melting and interior floor warming and space heating products. Call your Heatizon dealer for a free consultation or visit our website at www.heatizon.com

Heatizon Systems
1-888-239-1232

Download this Brochure in PDF or go Back to Heatizon Home