<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Heatwave Archives - Heatizon Systems</title>
	<atom:link href="https://www.heatizon.com/ufaq-category/heatwave/feed" rel="self" type="application/rss+xml" />
	<link>https://www.heatizon.com/ufaq-category/heatwave</link>
	<description></description>
	<lastBuildDate>Tue, 17 Mar 2020 17:54:53 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.2</generator>

<image>
	<url>https://www.heatizon.com/wp-content/uploads/2020/06/cropped-favicon-32x32.png</url>
	<title>Heatwave Archives - Heatizon Systems</title>
	<link>https://www.heatizon.com/ufaq-category/heatwave</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>How do I upgrade my thermostat to a touchscreen thermostat?</title>
		<link>https://www.heatizon.com/ufaqs/how-do-i-upgrade-my-thermostat-to-a-touchscreen-thermostat</link>
		
		<dc:creator><![CDATA[jallen]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 17:54:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.heatizon.com/?post_type=ufaq&#038;p=5544</guid>

					<description><![CDATA[<p>To upgrade the standard programmable thermostat (M429) to a programmable touchscreen thermostat, visit http://tilewarming.com and purchase the $170.00 touchscreen thermostat (M429-TS). Once you receive your new thermostat, send back the thermostat you received with your original Amazon order to the following address (You are responsible for paying return shipping costs), and you will receive a credit [&#8230;]</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/how-do-i-upgrade-my-thermostat-to-a-touchscreen-thermostat">How do I upgrade my thermostat to a touchscreen thermostat?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>To upgrade the standard programmable thermostat (M429) to a programmable touchscreen thermostat, visit <a href="http://tilewarming.com">http://tilewarming.com</a> and purchase the $170.00 touchscreen thermostat (M429-TS). Once you receive your new thermostat, send back the thermostat you received with your original Amazon order to the following address (You are responsible for paying return shipping costs), and you will receive a credit of $125.00 on your earlier order of $170.00, making the total $45.</p>
<p>Send thermostats for credit to:</p>
<p>THERMOSTAT UPGRADE<br />
Heatizon Systems<br />
4137 South 500 West<br />
Murray, UT 84123</p>
<p>NOTE: Please properly package thermostat to ensure that it does not get damaged in return shipping. Use a shipping method that allows for tracking of the unit to verify delivery. No express shipping is required.</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/how-do-i-upgrade-my-thermostat-to-a-touchscreen-thermostat">How do I upgrade my thermostat to a touchscreen thermostat?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Can I get a WIFI Thermostat?</title>
		<link>https://www.heatizon.com/ufaqs/can-i-get-a-wifi-thermostat</link>
		
		<dc:creator><![CDATA[jallen]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 17:33:43 +0000</pubDate>
				<guid isPermaLink="false">https://www.heatizon.com/?post_type=ufaq&#038;p=5543</guid>

					<description><![CDATA[<p>We do have a WIFI enabled thermstat available for the Heatwave system, however we keep a limited supply on-hand due the higher price of the unit. Please contact us about the availablity of these units. 1.888.239.1232</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/can-i-get-a-wifi-thermostat">Can I get a WIFI Thermostat?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>We do have a WIFI enabled thermstat available for the Heatwave system, however we keep a limited supply on-hand due the higher price of the unit. Please contact us about the availablity of these units. 1.888.239.1232</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/can-i-get-a-wifi-thermostat">Can I get a WIFI Thermostat?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Can I add multiple mats/cables to the thermostat to increase the size?</title>
		<link>https://www.heatizon.com/ufaqs/can-i-add-multiple-mats-cables-to-the-thermostat-to-increase-the-size</link>
		
		<dc:creator><![CDATA[jallen]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 17:30:29 +0000</pubDate>
				<guid isPermaLink="false">https://www.heatizon.com/?post_type=ufaq&#038;p=5542</guid>

					<description><![CDATA[<p>In most cases it is possible to increase the square footage of the Heatwave system to accommodate larger spaces.  Please contact us for more information about this application. 1.888.239.1232</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/can-i-add-multiple-mats-cables-to-the-thermostat-to-increase-the-size">Can I add multiple mats/cables to the thermostat to increase the size?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>In most cases it is possible to increase the square footage of the Heatwave system to accommodate larger spaces.  Please contact us for more information about this application. 1.888.239.1232</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/can-i-add-multiple-mats-cables-to-the-thermostat-to-increase-the-size">Can I add multiple mats/cables to the thermostat to increase the size?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Where do I get a manual for the thermostat?</title>
		<link>https://www.heatizon.com/ufaqs/where-do-i-get-a-manual-for-the-thermostat</link>
		
		<dc:creator><![CDATA[jallen]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 17:27:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.heatizon.com/?post_type=ufaq&#038;p=5541</guid>

					<description><![CDATA[<p>The complete user manual is available here: M429 User Manual</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/where-do-i-get-a-manual-for-the-thermostat">Where do I get a manual for the thermostat?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The complete user manual is available here: <a href="https://www.heatizon.com/download/m429m429pm-programmable-thermostat-power-module-wfloor-sensor-gfci-instructions?wpdmdl=3508">M429 User Manual</a></p>
<p>The post <a href="https://www.heatizon.com/ufaqs/where-do-i-get-a-manual-for-the-thermostat">Where do I get a manual for the thermostat?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Can the red heating cable be cut and shortened?</title>
		<link>https://www.heatizon.com/ufaqs/can-the-red-heating-cable-be-cut-and-shortened</link>
		
		<dc:creator><![CDATA[jallen]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 17:25:49 +0000</pubDate>
				<guid isPermaLink="false">https://www.heatizon.com/?post_type=ufaq&#038;p=5540</guid>

					<description><![CDATA[<p>No.</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/can-the-red-heating-cable-be-cut-and-shortened">Can the red heating cable be cut and shortened?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h1><em><strong>No.</strong></em></h1>
<p>The post <a href="https://www.heatizon.com/ufaqs/can-the-red-heating-cable-be-cut-and-shortened">Can the red heating cable be cut and shortened?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Our system got cut/damaged, what do we do?</title>
		<link>https://www.heatizon.com/ufaqs/our-system-got-cut-damaged-what-do-we-do</link>
		
		<dc:creator><![CDATA[jallen]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 17:24:59 +0000</pubDate>
				<guid isPermaLink="false">https://www.heatizon.com/?post_type=ufaq&#038;p=5539</guid>

					<description><![CDATA[<p>In the event that an accident has occurred and the heating element needs to be repaired, please visit: http://www.radiantshop.com/repairkit to purchase a repair kit. NOTE: This will have enough materials to do ONE repair. DO NOT repair the system more than two (2) times.</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/our-system-got-cut-damaged-what-do-we-do">Our system got cut/damaged, what do we do?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>In the event that an accident has occurred and the heating element needs to be repaired, please visit: <a href="http://www.radiantshop.com/repairkit">http://www.radiantshop.com/repairkit</a> to purchase a repair kit. NOTE: This will have enough materials to do ONE repair. DO NOT repair the system more than two (2) times.</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/our-system-got-cut-damaged-what-do-we-do">Our system got cut/damaged, what do we do?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How much thinset/mortar do I have to use for the heating cable?</title>
		<link>https://www.heatizon.com/ufaqs/how-much-thinset-mortar-do-i-have-to-use-for-the-heating-cable</link>
		
		<dc:creator><![CDATA[jallen]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 17:11:23 +0000</pubDate>
				<guid isPermaLink="false">https://www.heatizon.com/?post_type=ufaq&#038;p=5537</guid>

					<description><![CDATA[<p>The cable and connection points MUST be completely embedded so that you cannot see the red cable or connection points, there is no maximum depth of thinset/mortar.</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/how-much-thinset-mortar-do-i-have-to-use-for-the-heating-cable">How much thinset/mortar do I have to use for the heating cable?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The cable and connection points MUST be completely embedded so that you cannot see the red cable or connection points, there is no maximum depth of thinset/mortar.</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/how-much-thinset-mortar-do-i-have-to-use-for-the-heating-cable">How much thinset/mortar do I have to use for the heating cable?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>What can I use to keep the mat/cable down or secure it to the floor?</title>
		<link>https://www.heatizon.com/ufaqs/what-can-i-use-to-keep-the-mat-cable-down-or-secure-it-to-the-floor</link>
		
		<dc:creator><![CDATA[jallen]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 17:09:25 +0000</pubDate>
				<guid isPermaLink="false">https://www.heatizon.com/?post_type=ufaq&#038;p=5536</guid>

					<description><![CDATA[<p>There are a few methods to secure the cable to the floor until it is embedded: Use a small amount of tape to hold the cable tot he floor. (do not cover ALL of the cable, just use small perpendicular strips to secure it) Hot glue is acceptable, provided that the tip of the glue [&#8230;]</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/what-can-i-use-to-keep-the-mat-cable-down-or-secure-it-to-the-floor">What can I use to keep the mat/cable down or secure it to the floor?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>There are a few methods to secure the cable to the floor until it is embedded:</p>
<ol>
<li>Use a small amount of tape to hold the cable tot he floor. (do not cover ALL of the cable, just use small perpendicular strips to secure it)</li>
<li>Hot glue is acceptable, provided that the tip of the glue gun DOES NOT touch the heating element. Do a small drop on the floor and press the heating cable into the drop.</li>
<li>The mat comes with a tape on one side of the mat to aid in securing it to the floor.</li>
<li>Staples may be used on the mesh portion of the mat. (DO NOT STAPLE THE RED HEATING CABLE)</li>
</ol>
<p>The post <a href="https://www.heatizon.com/ufaqs/what-can-i-use-to-keep-the-mat-cable-down-or-secure-it-to-the-floor">What can I use to keep the mat/cable down or secure it to the floor?</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>I don&#8217;t want to use the schedule and want a set temperature all the time.</title>
		<link>https://www.heatizon.com/ufaqs/i-dont-want-to-use-the-schedule-and-want-a-set-temperature-all-the-time</link>
		
		<dc:creator><![CDATA[jallen]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 17:03:17 +0000</pubDate>
				<guid isPermaLink="false">https://www.heatizon.com/?post_type=ufaq&#038;p=5535</guid>

					<description><![CDATA[<p>Should you wish to bypass the various scheduling options on the M429 thermostat, follow the following procedures: Press the OK button twice to activate the main menu. Use the UP or DOWN buttons to scroll to MODE, then press OK. Use the UP or DOWN buttons to scroll to MAN. MODE, then press OK. Set [&#8230;]</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/i-dont-want-to-use-the-schedule-and-want-a-set-temperature-all-the-time">I don&#8217;t want to use the schedule and want a set temperature all the time.</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Should you wish to bypass the various scheduling options on the M429 thermostat, follow the following procedures:</p>
<ol>
<li>Press the OK button twice to activate the main menu.</li>
<li>Use the UP or DOWN buttons to scroll to MODE, then press OK.</li>
<li>Use the UP or DOWN buttons to scroll to MAN. MODE, then press OK.</li>
<li>Set desired temperature and press the OK button.</li>
<li>Use the UP or DOWN buttons to scroll to EXIT, then press OK.</li>
<li>Your thermostat will now maintain the set temperature. (Note: power bumps/losses may reset the thermostat back to a pre-programed schedule.)</li>
</ol>
<p>NOTE: Using the thermostat in this manner may cause excessive power usage, especially if the space is inadequately insulated and/or the desired temperature is very high.</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/i-dont-want-to-use-the-schedule-and-want-a-set-temperature-all-the-time">I don&#8217;t want to use the schedule and want a set temperature all the time.</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>The thermostat says &#8220;E2?&#8221;</title>
		<link>https://www.heatizon.com/ufaqs/the-thermostat-says-e2</link>
		
		<dc:creator><![CDATA[jallen]]></dc:creator>
		<pubDate>Tue, 17 Mar 2020 16:57:32 +0000</pubDate>
				<guid isPermaLink="false">https://www.heatizon.com/?post_type=ufaq&#038;p=5534</guid>

					<description><![CDATA[<p>This is a sensor problem, here are a few fixes: Check to ensure the thermostat is firmly connected to the &#8220;C&#8221; and &#8220;D&#8221; ports behind the face plate of the thermostat. If you did not install a floor sensor or it is damaged, set the thermostat to red ambient temperature: Press the OK button twice [&#8230;]</p>
<p>The post <a href="https://www.heatizon.com/ufaqs/the-thermostat-says-e2">The thermostat says &#8220;E2?&#8221;</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>This is a sensor problem, here are a few fixes:</p>
<ol>
<li>Check to ensure the thermostat is firmly connected to the &#8220;C&#8221; and &#8220;D&#8221; ports behind the face plate of the thermostat.</li>
<li>If you did not install a floor sensor or it is damaged, set the thermostat to red ambient temperature:
<ol>
<li>Press the OK button twice to bring up the main menu.</li>
<li>Use the UP or DOWN buttons to scroll to SETTINGS, then press OK.</li>
<li>Use the UP or DOWN buttons to scroll to APPLICATION, then press OK.</li>
<li>Use the UP or DOWN buttons to select ROOM, then press OK.</li>
<li>Set desired temperature (some model of thermostat)</li>
<li>Use the UP or DOWN buttons to scroll to EXIT, then press OK. (do this twice)</li>
<li>Your thermostat will now measure the temperature of the room and NOT the floor sensor. (TIP: You may have to adjust the thermostat temperature higher or lower than expected to achieve desired floor temperature.)</li>
</ol>
</li>
<li>Test the floor sensor to measure resistance to check for resistance.
<ol>
<li>Set your multimeter to the 200k Ohm (Ω) setting.</li>
<li>touch a probe to each end of the sensor wire.</li>
<li>A functioning floor sensor should get a reading between 9,000 and 25,000 ohms, if the sensor fails this test, please see #2 for how to switch to ambient air sensor.</li>
</ol>
</li>
</ol>
<p><em><strong>NOTE: Whenever working on ANY wiring for the thermostat, please TURN OFF the breaker powering the thermostat and floor heating system.</strong></em></p>
<p>The post <a href="https://www.heatizon.com/ufaqs/the-thermostat-says-e2">The thermostat says &#8220;E2?&#8221;</a> appeared first on <a href="https://www.heatizon.com">Heatizon Systems</a>.</p>
]]></content:encoded>
					
		
		