<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>2. Heatwave System Archives -</title>
	<atom:link href="https://www.heatizon.com/heatwave/category/installation/heatwave-system/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.heatizon.com/heatwave/category/installation/heatwave-system/</link>
	<description></description>
	<lastBuildDate>Fri, 18 Feb 2022 17:58:39 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>
	<item>
		<title>Heatwave System</title>
		<link>https://www.heatizon.com/heatwave/2022/02/15/heatwave-system/</link>
		
		<dc:creator><![CDATA[jallen]]></dc:creator>
		<pubDate>Tue, 15 Feb 2022 23:32:46 +0000</pubDate>
				<category><![CDATA[2. Heatwave System]]></category>
		<guid isPermaLink="false">https://www.heatizon.com/heatwave/?p=239</guid>

					<description><![CDATA[<p>2.1 Heatwave Specifications MATS CABLES Cable Construction Twin Conductor Twin Conductor Rated Voltage 120V, 240V 120V, 240V Output 12W/ft2 (130W/m2) ± 10% 2.73 to 4.36W.ft (8.66 to 14.30W/m) ± 10% Cable Spacing 3” (76.2mm) 2.5” to 4.5” (64.5mm to 114.3mm) Cable Diameter 1/8” to 1/6” (3.2mm to 4.2mm) 1/8” to 1/6” (3.2mm to 4.2mm) Conductor [&#8230;]</p>
<p>The post <a href="https://www.heatizon.com/heatwave/2022/02/15/heatwave-system/">Heatwave System</a> appeared first on <a href="https://www.heatizon.com/heatwave"></a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex">
<div class="wp-block-button"><a class="wp-block-button__link has-luminous-vivid-amber-color has-black-background-color has-text-color has-background" href="https://www.heatizon.com/heatwave/2022/02/15/general-guidelines/" style="border-radius:5px">Previous Step</a></div>
</div>



<p></p>



<h3 class="wp-block-heading" id="2-1-heatwave-specifications">2.1 Heatwave Specifications</h3>



<figure class="wp-block-table is-style-stripes has-small-font-size"><table><tbody><tr><td></td><td><strong>MATS</strong></td><td><strong>CABLES</strong></td></tr><tr><td><strong>Cable Construction</strong></td><td>Twin Conductor</td><td>Twin Conductor</td></tr><tr><td><strong>Rated Voltage</strong></td><td>120V, 240V</td><td>120V, 240V</td></tr><tr><td><strong>Output</strong></td><td>12W/ft<sup>2</sup> (130W/m2) ± 10%</td><td>2.73 to 4.36W.ft (8.66 to 14.30W/m) ± 10%</td></tr><tr><td><strong>Cable Spacing</strong></td><td>3” (76.2mm)</td><td>2.5” to 4.5” (64.5mm to 114.3mm)</td></tr><tr><td><strong>Cable Diameter</strong></td><td>1/8” to 1/6” (3.2mm to 4.2mm)</td><td>1/8” to 1/6” (3.2mm to 4.2mm)</td></tr><tr><td><strong>Conductor Insulation</strong></td><td>Fluoropolymer</td><td>Fluoropolymer</td></tr><tr><td><strong>Outer Insulation</strong></td><td>Fluoropolymer or TPE</td><td>Fluoropolymer or TPE</td></tr><tr><td><strong>Max. Ambient Temp.</strong></td><td>85°F (30°C)</td><td>85°F (30°C)</td></tr><tr><td><strong>Min Installation Temp</strong></td><td>40°F (5°C)</td><td>40°F (5°C)</td></tr><tr><td><strong>Cold Lead</strong></td><td>2-wire heating conductor plus ground braid; 15 ft (4.57 M)</td><td>2-wire heating conductor plus ground braid; 15 ft (4.57 M)</td></tr></tbody></table></figure>



<h3 class="wp-block-heading" id="2-2-sample-thermostat-specifications">2.2 Sample Thermostat Specifications</h3>



<figure class="wp-block-table is-style-stripes"><table><tbody><tr><td><strong>Cable Construction</strong></td><td>On/Off Control</td></tr><tr><td><strong>Rated Voltage</strong></td><td>120/240V ± 15%, 50/60 Hz</td></tr><tr><td><strong>Output</strong></td><td>15 AMP</td></tr><tr><td><strong>Cable Spacing</strong></td><td>40° to 104°F (5° to 40°C)</td></tr><tr><td><strong>Cable Diameter</strong></td><td>32° to 104°F (0° to 40°C)</td></tr><tr><td><strong>Conductor Insulation</strong></td><td>2-wire, 10 foot lead wire</td></tr></tbody></table></figure>



<h3 class="wp-block-heading" id="2-3-heatwave-typical-installations-and-applications">2.3 Heatwave® typical installations and applications</h3>



<figure class="wp-block-image size-large"><img  title="" fetchpriority="high" decoding="async" width="1024" height="211" src="https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/Schematic-with-Labels-Heatwave-Concrete-1024x211.jpg"  alt="Schematic-with-Labels-Heatwave-Concrete-1024x211 Heatwave System"  class="wp-image-242" srcset="https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/Schematic-with-Labels-Heatwave-Concrete-1024x211.jpg 1024w, https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/Schematic-with-Labels-Heatwave-Concrete-300x62.jpg 300w, https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/Schematic-with-Labels-Heatwave-Concrete-768x158.jpg 768w, https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/Schematic-with-Labels-Heatwave-Concrete-1536x316.jpg 1536w, https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/Schematic-with-Labels-Heatwave-Concrete-2048x421.jpg 2048w" sizes="(max-width: 1024px) 100vw, 1024px" /></figure>



<figure class="wp-block-image size-large"><img  title="" decoding="async" width="1024" height="311" src="https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/Schematic-Heatwave-Labels-Insulation-1024x311.jpg"  alt="Schematic-Heatwave-Labels-Insulation-1024x311 Heatwave System"  class="wp-image-241" srcset="https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/Schematic-Heatwave-Labels-Insulation-1024x311.jpg 1024w, https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/Schematic-Heatwave-Labels-Insulation-300x91.jpg 300w, https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/Schematic-Heatwave-Labels-Insulation-768x234.jpg 768w, https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/Schematic-Heatwave-Labels-Insulation-1536x467.jpg 1536w, https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/Schematic-Heatwave-Labels-Insulation-2048x623.jpg 2048w" sizes="(max-width: 1024px) 100vw, 1024px" /></figure>



<p><strong>Alternative method:</strong> self-leveling cement is recommended for large surfaces and the following floor materials: engineered wood, laminate, floating floors, vinyl, linoleum and carpet.</p>



<p></p>



<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:10%">
<figure class="wp-block-image size-full is-resized"><img  title="" decoding="async" src="https://www.heatizon.com/heatwave/wp-content/uploads/2022/02/warning-sign.jpg"  alt="warning-sign Heatwave System"  class="wp-image-232" width="100" height="100"/></figure>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:90%">
<p style="font-size:24px"><strong><em>Consult the manufacturer for information on special installation requirements for carpets, wood, laminate and vinyl or linoleum flooring.</em></strong></p>
</div>
</div>



<ul class="has-background wp-block-list" style="background-color:#f9ff00"><li>Read the instructions carefully before installing Heatwave® system.</li><li>Remember to measure the resistance four times.</li><li>Do not install Heatwave® in walls or ceilings.</li><li><strong>The cable must be embedded in cementitious material.</strong></li><li>The minimum installation temperature is 40ºF (5°C ).</li><li>The heating cable cannot be cut to length, crossed over itself, or installed too close to itself.</li><li>Use copper conductor feeder wire only.</li><li>Remember to check that the supply voltage matches the voltage of the Heatwave.</li><li>Remember to place the labels as written in this instruction.</li><li>Only for indoor installation.</li><li>Metal structures or materials used for the support of or on which the Heatwave® is installed must be grounded in accordance with applicable CSA or NEC requirements.<br><br>Please consult Heatizon Systems for any other questions.</li></ul>



<div class="wp-block-buttons is-content-justification-right is-layout-flex wp-container-core-buttons-is-layout-765c4724 wp-block-buttons-is-layout-flex">
<div class="wp-block-button"><a class="wp-block-button__link has-black-color has-luminous-vivid-amber-background-color has-text-color has-background" href="https://www.heatizon.com/heatwave/2022/02/15/floor-heating-installation-design/" style="border-radius:5px">Next Step</a></div>
</div>



<hr class="wp-block-separator"/>



<h2 class="wp-block-heading" id="jump-to-section">Jump to Section</h2>


<ul class="wp-block-categories-list wp-block-categories">	<li class="cat-item cat-item-26"><a href="https://www.heatizon.com/heatwave/category/installation/general-guidelines/">1. General Guidelines</a>
</li>
	<li class="cat-item cat-item-27 current-cat"><a aria-current="page" href="https://www.heatizon.com/heatwave/category/installation/heatwave-system/">2. Heatwave System</a>
</li>
	<li class="cat-item cat-item-28"><a href="https://www.heatizon.com/heatwave/category/installation/3-floor-heating-design/">3. Floor Heating Design</a>
</li>
	<li class="cat-item cat-item-29"><a href="https://www.heatizon.com/heatwave/category/installation/4-product-selection/">4. Product Selection</a>
</li>
	<li class="cat-item cat-item-30"><a href="https://www.heatizon.com/heatwave/category/installation/5-installation/">5. Installation</a>
</li>
	<li class="cat-item cat-item-31"><a href="https://www.heatizon.com/heatwave/category/installation/6-completing-installation/">6. Completing Installation</a>
</li>
	<li class="cat-item cat-item-32"><a href="https://www.heatizon.com/heatwave/category/installation/7-commissioning/">7. Commissioning</a>
</li>
	<li class="cat-item cat-item-33"><a href="https://www.heatizon.com/heatwave/category/installation/8-heatwave-expansion/">8. Heatwave Expansion</a>
</li>
	<li class="cat-item cat-item-34"><a href="https://www.heatizon.com/heatwave/category/installation/9-thermostat-quick-start/">9. Thermostat Quick Start</a>
</li>
	<li class="cat-item cat-item-37"><a href="https://www.heatizon.com/heatwave/category/installation/final-steps/">Final Steps</a>
</li>
	<li class="cat-item cat-item-24 current-cat-parent current-cat-ancestor"><a href="https://www.heatizon.com/heatwave/category/installation/">Installation</a>
</li>
	<li class="cat-item cat-item-25"><a href="https://www.heatizon.com/heatwave/category/installation/introduction-warnings/">Introduction &amp; Warnings</a>
</li>
</ul><p>The post <a href="https://www.heatizon.com/heatwave/2022/02/15/heatwave-system/">Heatwave System</a> appeared first on <a href="https://www.heatizon.com/heatwave"></a>.</p>