<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Surface Installation Archives -</title>
	<atom:link href="https://www.heatizon.com/snowmeltz/category/installation/surface-installation/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.heatizon.com/snowmeltz/category/installation/surface-installation/</link>
	<description></description>
	<lastBuildDate>Wed, 22 Jun 2022 15:21:39 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>
	<item>
		<title>Surface Application</title>
		<link>https://www.heatizon.com/snowmeltz/2022/03/02/surface-application/</link>
		
		<dc:creator><![CDATA[jallen]]></dc:creator>
		<pubDate>Wed, 02 Mar 2022 15:51:59 +0000</pubDate>
				<category><![CDATA[Surface Installation]]></category>
		<guid isPermaLink="false">https://www.heatizon.com/snowmeltz/?p=192</guid>

					<description><![CDATA[<p>For Concrete Applications: Proceed with applying concrete. Ensure that the concrete covers the entire heating element and the connection between the heating cable and cold leads. Great care should be taken to not damage the heating cables by impacting, cutting or other abuse. For Asphalt Applications: Heatizon Systems heating cable is of high quality and [&#8230;]</p>
<p>The post <a href="https://www.heatizon.com/snowmeltz/2022/03/02/surface-application/">Surface Application</a> appeared first on <a href="https://www.heatizon.com/snowmeltz"></a>.</p>
]]></description>
										<content:encoded><![CDATA[
<div class="wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex">
<div class="wp-block-button"><a class="wp-block-button__link has-pale-cyan-blue-color has-text-color" href="https://www.heatizon.com/snowmeltz/2022/03/02/install-activation-device/" style="border-radius:10px">Previous Step</a></div>
</div>



<h3 class="wp-block-heading">For Concrete Applications: </h3>



<div class="wp-block-image"><figure class="alignright size-large is-resized"><img  title="" decoding="async" src="https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/DSCN0318-768x1024.jpg"  alt="DSCN0318-768x1024 Surface Application"  class="wp-image-193" width="140" height="187" srcset="https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/DSCN0318-768x1024.jpg 768w, https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/DSCN0318-225x300.jpg 225w, https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/DSCN0318-1152x1536.jpg 1152w, https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/DSCN0318-1536x2048.jpg 1536w, https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/DSCN0318-scaled.jpg 1920w" sizes="(max-width: 140px) 100vw, 140px" /></figure></div>



<p>Proceed with applying concrete. Ensure that the concrete covers the entire heating element and the connection between the heating cable and cold leads. Great care should be taken to not damage the heating cables by impacting, cutting or other abuse.</p>



<h3 class="wp-block-heading">For Asphalt Applications:</h3>



<p>Heatizon Systems heating cable is of high quality and durable construction. As a result, it can tolerate the heat and compression of newly poured asphalt with some modification. The heating cables can tolerate 464°F(240°C) for 30 minutes. For single pour asphalt, cover the heating element with 1/2” of substrate material prior to installing asphalt per the directions below. For both single and two pour asphalt installations place a layer of asphalt at least 1/2 inch thick over the cables by hand, and roll with a roller of approximately 1.5 ton size. This will protect the heating cables from damage by tools or paving equipment and will protect the cable from heat during placement of the main pour. Continuously check the insulation resistance of the heating cables to verify that the cables are not damaged during placement of the asphalt. Continue with the main pour.</p>



<figure class="wp-block-image size-large"><img  title="" fetchpriority="high" decoding="async" width="1024" height="211" src="https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/asphalt-smz-1024x211.jpg"  alt="asphalt-smz-1024x211 Surface Application"  class="wp-image-194" srcset="https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/asphalt-smz-1024x211.jpg 1024w, https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/asphalt-smz-300x62.jpg 300w, https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/asphalt-smz-768x158.jpg 768w, https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/asphalt-smz-1536x316.jpg 1536w, https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/asphalt-smz.jpg 2000w" sizes="(max-width: 1024px) 100vw, 1024px" /></figure>



<h3 class="wp-block-heading">For Paver Applications:</h3>



<div class="wp-block-image"><figure class="alignleft size-large is-resized"><img  title="" decoding="async" src="https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/59337900782__2EC869CF-D793-4C28-8EF0-F7426C8E3E51-e1646235955470-768x1024.jpg"  alt="59337900782__2EC869CF-D793-4C28-8EF0-F7426C8E3E51-e1646235955470-768x1024 Surface Application"  class="wp-image-195" width="206" height="275" srcset="https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/59337900782__2EC869CF-D793-4C28-8EF0-F7426C8E3E51-e1646235955470-768x1024.jpg 768w, https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/59337900782__2EC869CF-D793-4C28-8EF0-F7426C8E3E51-e1646235955470-225x300.jpg 225w, https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/59337900782__2EC869CF-D793-4C28-8EF0-F7426C8E3E51-e1646235955470-1152x1536.jpg 1152w, https://www.heatizon.com/snowmeltz/wp-content/uploads/2022/03/59337900782__2EC869CF-D793-4C28-8EF0-F7426C8E3E51-e1646235955470.jpg 1512w" sizes="(max-width: 206px) 100vw, 206px" /></figure></div>



<p>Proceed with the installation by covering the heating cable with a layer of sand or stone dust. Ensure that the sand or stone dust covers the entire heating element and the connection between the heating element and cold leads before the pavers are installed. Great care should be taken to not damage the heating cables by impacting, cutting or other abuse.</p>



<h3 class="wp-block-heading">For Stone or Tile with Mortar Applications:</h3>



<p>Cover the heating cable with mortar to completely embed them and allow it to set. Allowing the first layer of mortar to set will protect the heating cables during the final installation and the setting bed for stone or tile. Install the Stone or Tile and keep note that the final cable depth of the cable from the surface should be 2”. Great care should be taken to not damage the heating cables by impacting, cutting or other abuse.</p>



<div class="wp-block-buttons is-content-justification-right is-layout-flex wp-container-core-buttons-is-layout-765c4724 wp-block-buttons-is-layout-flex">
<div class="wp-block-button"><a class="wp-block-button__link has-pale-cyan-blue-color has-text-color" href="https://www.heatizon.com/snowmeltz/2022/03/02/electrical-connections/" style="border-radius:10px">Next Step</a></div>
</div>



<hr class="wp-block-separator"/>



<h2 class="wp-block-heading">Jump to a section</h2>


<ul class="wp-block-categories-list wp-block-categories">	<li class="cat-item cat-item-28"><a href="https://www.heatizon.com/snowmeltz/category/installation/introduction/">Introduction</a>
</li>
	<li class="cat-item cat-item-15"><a href="https://www.heatizon.com/snowmeltz/category/installation/warnings-guidelines/">Warnings &amp; Guidelines</a>
</li>
	<li class="cat-item cat-item-14"><a href="https://www.heatizon.com/snowmeltz/category/installation/suggestions/">Suggestions</a>
</li>
	<li class="cat-item cat-item-16"><a href="https://www.heatizon.com/snowmeltz/category/installation/snowmeltz-information/">SnowMeltz Information</a>
</li>
	<li class="cat-item cat-item-18"><a href="https://www.heatizon.com/snowmeltz/category/installation/product-selection/">Product Selection</a>
</li>
	<li class="cat-item cat-item-21"><a href="https://www.heatizon.com/snowmeltz/category/installation/installation-design/">Installation Design</a>
</li>
	<li class="cat-item cat-item-19"><a href="https://www.heatizon.com/snowmeltz/category/installation/required-tests/">Required Tests</a>
</li>
	<li class="cat-item cat-item-20"><a href="https://www.heatizon.com/snowmeltz/category/installation/area-prep/">Area Prep</a>
</li>
	<li class="cat-item cat-item-22"><a href="https://www.heatizon.com/snowmeltz/category/installation/installation-installation/">Installation</a>
</li>
	<li class="cat-item cat-item-23"><a href="https://www.heatizon.com/snowmeltz/category/installation/activation-device/">Activation Device</a>
</li>
	<li class="cat-item cat-item-24 current-cat"><a aria-current="page" href="https://www.heatizon.com/snowmeltz/category/installation/surface-installation/">Surface Installation</a>
</li>
	<li class="cat-item cat-item-25"><a href="https://www.heatizon.com/snowmeltz/category/installation/electrical-connections/">Electrical Connections</a>
</li>
	<li class="cat-item cat-item-26"><a href="https://www.heatizon.com/snowmeltz/category/installation/quick-start-guides/">Quick Start Guides</a>
</li>
	<li class="cat-item cat-item-27"><a href="https://www.heatizon.com/snowmeltz/category/installation/warranty-forms/">Warranty &amp; Forms</a>
</li>
</ul><p>The post <a href="https://www.heatizon.com/snowmeltz/2022/03/02/surface-application/">Surface Application</a> appeared first on <a href="https://www.heatizon.com/snowmeltz"></a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
