GutterMelt is a high quality self regulating heating element used to melt snow and ice from gutters and downspouts. GutterMelt can also be used for heat tracing along eaves and valleys when the roof covering cannot be removed for ZMesh, Invizimelt, or Tuff Cable Heatsink applications as a retrofit option.
Features:
GutterMelt Applications : Keep the water flowing to the ground with Heatizon GutterMelt. GutterMelt comes in several outputs to meet residential and industrial applications. Two runs of cable are recommended for common applications in gutters and downspouts.
- Roof Eaves
- Roof Valleys
- Gutters
- Downspouts
- Pipe Tracing
- Industrial Applications
|
 |
Technical Tables:
Required GutterMelt |
Roof Overhang |
B |
A |
Spacing Factor |
Heating Width |
Heating Height |
12" |
2ft |
18" |
2 |
24" |
2ft |
30" |
3 |
36" |
2ft |
42" |
4 |
|
|
| |
|
Maximum Allowable Circuit Lenghts per Breaker Rating for Heating Cable |
| |
GutterMelt 6W/ft |
GutterMelt 12W/ft |
| |
@ 32°F in ice water |
@ 32°F in ice water |
| |
120V |
120V |
Startup@0°F
Startup@-20°F |
15A
90 ft 75 ft |
20A
120 ft
100 ft |
30A
175 ft
150 ft |
15A
80 ft
70 ft |
20A
105 ft
95 ft |
30A
160 ft
145 ft |
| |
240V |
240V |
Startup@0°F
Startup@-20°F |
15A
135 ft
120 ft |
20A
185 ft
160 ft |
30A
275 ft
250 ft |
15A
160 ft
145 ft |
20A
210 ft
195 ft |
30A
320 ft
295 ft |
| |
|
|
|
|
|
|
|
|