UL 508A certified panel shop — custom control panels engineered to project specifications. 120V to 480V. GFEP or non-GFEP. BMS/BAS integration. All enclosure types. Standard panels available for immediate shipment.

Heatizon is a UL 508A certified panel shop — one of very few radiant heating manufacturers in the United States licensed to engineer, assemble, and list custom control panels to the UL 508A standard for Industrial Control Panels. Custom panels are engineered to project-specific voltage, circuit, enclosure, activation, and integration requirements — shipped complete with wiring diagrams and backed by full end-user support. For straightforward installations, Heatizon also offers a complete line of standard off-the-shelf panels with GFEP protection, ready to ship.

What UL 508A certification means for your project

UL 508A is the governing standard for Industrial Control Panels — the certification required for panel assemblies that integrate breakers, relays, indicators, and controllers into a listed unit. For commercial and industrial radiant heating projects subject to electrical inspection, a UL 508A listed panel is typically required. Heatizon’s panel shop designs and builds to this standard, meaning every custom panel ships as a listed assembly verifiable by inspectors and authority having jurisdiction — not a field-assembled collection of individual components.

Custom panel capabilities

Heatizon custom panels are engineered to each project’s specific requirements:

  • Voltages: 120V, 208V, 240V, 277V, and 480V
  • Breakers: GFEP or non-GFEP, sized to circuit loads
  • Enclosures: All types — NEMA-rated stainless steel, standard, indoor, outdoor, and wet location
  • Activation integration: Snow and ice sensors, temperature sensors, moisture sensors, programmable thermostats, and manual overrides — single activator or independently zoned per circuit
  • BMS/BAS integration: Panels can relay current monitoring, fault signals, and activation status to Building Management and Building Automation Systems – For complete smart snow melt panel systems, see HZ-ICE — Heatizon’s monitored panel with BACnet/IP integration.
  • Project-specific controls: Custom indicators, switches, and controllers configured to project requirements
  • Documentation: Complete wiring diagrams and full end-user support included with every panel

Multi-circuit configurations

Custom panels can house multiple breakers inside a single enclosure for large installations requiring multiple heating circuits — snow melting, floor heating, roof deicing, and heat trace circuits can all be managed from a single panel. Activation can be configured with a single activator controlling all circuits for uniformity, or with independently zoned activators per circuit for maximum operational flexibility.

Standard off-the-shelf panels

For projects that don’t require custom engineering, Heatizon’s standard panel line offers GFEP-protected panels with indicators, available for all voltages across a range of breaker sizes — in stock and ready to ship. Standard panels are appropriate for straightforward single or multi-circuit installations where project-specific customization is not required.

Why UL 508A matters

Most radiant heating manufacturers ship heating cable, thermostats, and relay panels as separate components, leaving electrical contractors to assemble the control panel in the field. Field assembly produces no listed panel — which creates complications for inspection, warranty, and liability on commercial and industrial projects. Heatizon’s UL 508A certified panel shop produces a complete, listed panel assembly engineered to the project’s specifications before it leaves the facility.

The UL 508A certification is issued specifically to the panel shop facility and the personnel in it — it is not a product certification but a manufacturing credential. Maintaining UL 508A certification requires ongoing compliance with UL’s manufacturing and quality standards. It is one of the most meaningful credentials available to distinguish a professional engineering capability from a product reseller.

From heating cable to control panel — a single listed source

Every Heatizon custom panel is designed around Heatizon’s own ETL-listed line-voltage heating products — Hott-Wire, GutterMelt, Outpipe, and Cozy Heat. For commercial and industrial projects requiring a complete, listed radiant heating system from heating element to control panel, Heatizon can supply and engineer every component from a single listed source. The panel is designed to the heating system, the heating system is designed to the load, and both ship together with full documentation.

Built by Heatizon — US manufacturer since 1979

Heatizon Systems has manufactured electric radiant heating products in the United States since 1979. The Custom Panel Builds service extends that manufacturing capability from heating cable to control panel engineering — bringing the same project-specific design approach that underpins every Heatizon heating system to the electrical control panel that manages it.

Frequently Asked Questions

Custom Panels

The choice depends on how many circuits the project requires. 6 or less use the 6-circuit panel and 6-12 circuits use the 12-circuit option. Currently, for projects above 12 circuits, multiple panels will be required. Both configurations use the same Intelligent Controller Electronics platform and integrate identically with building automation systems via BACnet/IP. Contact a Heatizon distributor with the zone count and load requirements for your project.

HZ-ICE is currently available in two configurations: a 6-circuit version for residential and smaller light-commercial installations, and a 12-circuit version for larger installations requiring more independent heating zones. Both configurations include the same per-zone current monitoring, BACnet/IP integration, local Wi-Fi dashboard, industrial battery backup, and OAT lockout — the 12-circuit version scales the zone count and panel capacity while maintaining the same intelligent control platform. Contact Heatizon to specify the right configuration for your project’s zone count and load requirements.

HZ-ICE stands for Intelligent Controller Electronics — reflecting the panel’s core distinction from standard contactor-based snow melt panels. The “intelligent” designation refers to the panel’s per-circuit current monitoring, real-time fault detection, BACnet/IP integration, and local Wi-Fi dashboard — capabilities that standard snow melt panels do not include. The HZ prefix identifies the product as part of the Heatizon family.

Yes. HZ-ICE is the recommended control panel for Heatizon’s patented pedestal paver and deck snow melt system. Hott-Wire MI cable is installed in the paver heating pans, and HZ-ICE monitors and controls each circuit — providing the full per-circuit current monitoring, fault detection, and BACnet integration of the smart panel platform with the reliability of Heatizon’s patented pan system.

HZ-ICE is designed for high-end residential and light commercial snow melt and floor heat installations where monitoring, accountability, and building automation integration are required. Primary applications include driveways/ramps with multiple heated surface zones, commercial properties where a snow incident becomes a liability, HOAs and property managers requiring remote visibility across multiple buildings, and mechanical contractors with existing BACnet infrastructure who need a snow melt/floor heat panel that integrates natively. HZ-ICE is also the right specification for any installation replacing a failed legacy panel where the customer needs proof the system is working.

Force-On Override allows the panel to run all enabled zones continuously for a specified duration regardless of what the snow sensor is detecting. It is useful for warming a surface before a special event, or for accelerating melt after a heavy storm has already deposited snow. The panel still respects the OAT lockout limits during Force-On — it will not heat if the outdoor temperature is above the high cutoff or below the low cutoff. The override runs for the duration specified and stops automatically.

The outdoor air temperature (OAT) lockout prevents HZ-ICE from activating heating in conditions where it is not useful or not appropriate. The default high cutoff is 40°F — above this temperature, snow melts on its own and heating is wasted energy. The default low cutoff is 20°F — below this temperature, the heating cables cannot keep up with the cold and the panel stops rather than run continuously. Both cutoffs are customer-adjustable from the dashboard. The OAT lockout remains active even during Force-On override, protecting the heating cables from running in conditions they were not designed for.

HZ-ICE is engineered to drive Heatizon’s family of heating cables. Hott-Wire MI cable is the primary recommendation for in-slab snow melting and pedestal paver snow melt installations. GutterMelt self-regulating cable is specified for roof valleys, gutters, and downspouts. Cozy Heat the preferred solution for heat loss prevention and floor/space heating. The panel is cable-agnostic in its electrical design — the cable is selected based on the surface and application, while the panel remains the same across all installations.

UL 508A listing is planned for production panels. HZ-ICE is assembled from UL-listed components throughout. For current listing status, contact Heatizon directly.

HZ-ICE accepts a variety of voltages and configurations dependent on the individual project. Enclosures vary based on project variables. The HZ-ICE panel itself requires 120V, 60hz power.

HZ-ICE includes an industrial DC UPS (with two 12V/5Ah sealed lead-acid batteries) that keeps the BACnet controller and alarm reporting active for approximately 7 hours after grid AC fails. The heating cables do not run on battery — there is not enough energy for that — but the panel’s intelligence stays active. The amber door pilot illuminates during battery operation. When grid power returns, the panel resumes normal operation automatically. The battery backup uses industrial-grade components rather than consumer UPS hardware, eliminating the replacement cycles associated with consumer battery backup products.

Each HZ-ICE zone is switched by a definite-purpose contactor. A welded contactor is one that has failed in the closed (on) position — it continues passing current even when the panel has commanded it off. HZ-ICE detects this condition by monitoring current in a zone that should be off: if current is flowing when the panel has not commanded that zone to heat, a welded contactor alarm is generated. This is a safety-critical fault — the affected zone should be disabled from the dashboard and service called immediately.

Each of HZ-ICE’s circuits is monitored by a dedicated current transformer. When the panel activates a circuit, it measures the current the circuit is drawing. If the circuit draws no current when it should be heating, the panel logs a load fault alarm — indicating the heating cable is broken, the breaker has tripped, or the circuit has otherwise failed. The alarm appears on the dashboard and is reported to the building automation system via BACnet. This detection happens automatically, without any manual inspection of the heating cable or driveway surface.

No. HZ-ICE is not connected to the internet. The panel’s Wi-Fi is a local access point — it only reaches approximately 30 feet from the panel and exists only for the local dashboard. No cloud service, no remote update capability, and no external access is possible without a building-side VPN or similar arrangement set up by the building’s IT team. Heatizon has no remote access to any HZ-ICE panel.

Yes. HZ-ICE exposes 35 BACnet/IP objects to the building automation system — compatible with any BACnet-capable BAS platform including Niagara, Metasys, and similar systems. No additional drivers or licensing are required. The BACnet controller (BACnet/IP certified) is battery-backed — it continues reporting to the BAS for approximately 7 hours after grid AC fails, so the building automation system receives outage notification before anyone else knows the panel is on battery. If the building does not have a BAS, the local Wi-Fi dashboard provides full visibility and control without any BACnet configuration.

Every HZ-ICE panel includes a built-in web dashboard hosted on the panel’s own Wi-Fi access point. No app installation, no account creation, and no connection to the building’s network is required. To access the dashboard, connect a phone, tablet, or laptop to the panel’s Wi-Fi network (the network name and password are on a label inside the panel door) and open any web browser. The dashboard shows real-time zone current draw, runtime hours, outdoor temperature, snow sensor status, battery health, and any active alarms — and allows adjustment of temperature cutoffs, zone enables, and manual override duration.

A standard contactor panel turns heating circuits on and off — and that is all it does. HZ-ICE monitors what is actually happening in each zone. Per-zone current sensing detects a broken heating cable the moment it fails — not when someone notices the driveway is still covered in snow in February. BACnet/IP integration exposes all panel signals to the building automation system. A local Wi-Fi dashboard lets anyone with a phone check panel health without opening the enclosure or calling a technician. Battery backup keeps alarm reporting running for approximately 7 hours after grid power fails.

HZ-ICE controls up to 6/12 independent heating circuits — each circuit is independantly switched by a project-specific voltage/amperage GFEP definite-purpose contactor and monitored by a dedicated current transformer. Each zone can be independently monitored and controlled. For installations requiring more than 12 zones, Heatizon will be offering larger circuit panels in the same smart platform family.

HZ-ICE is Heatizon’s smart multi-zone snow melt control panel for high-end residential and commercial installations. Unlike a standard relay panel, HZ-ICE monitors every zone individually — detecting broken heating cables, stuck contactors, and load faults in real time. Every panel includes a built-in local Wi-Fi web dashboard, BACnet/IP integration for building automation systems, and battery backup that keeps alarms reporting through grid power outages. HZ-ICE is engineered to drive Heatizon’s Hott-Wire, Cozy Heat, and GutterMelt heating cables across driveways, walkways, roof valleys, gutters, and pedestal paver systems.

Every Heatizon custom panel includes complete wiring diagrams and full end-user support. The panel is engineered to the project specifications, assembled in Heatizon’s UL 508A certified facility, and shipped ready for installation. Project-specific indicators, switches, and controllers are integrated as required.

Yes. In addition to custom-built panels, Heatizon offers a complete line of standard off-the-shelf panels with GFEP protection, indicators, and support for all voltages across a range of breaker sizes — available for immediate shipment. Standard panels are appropriate for straightforward installations where project-specific customization is not required.

Heatizon custom panels can integrate with a wide range of activation devices — including automatic snow and ice detection sensors, temperature sensors, moisture sensors, programmable thermostats, and manual overrides. Panels can be configured with a single activator controlling multiple circuits for uniformity, or with independently zoned activators for each circuit for maximum flexibility.

Yes. Heatizon custom panels can be configured to relay signals to Building Management Systems (BMS) and Building Automation Systems (BAS), enabling the radiant heating system to integrate with the building’s central control infrastructure. Current monitoring, fault signals, and activation status can all be relayed to the BMS/BAS depending on the project requirements.

All types of enclosures are available — including NEMA-rated stainless steel and standard enclosures — sized and specified to the project’s environment and installation location. Indoor, outdoor, wet location, and hazardous location enclosures can all be accommodated depending on the project requirements.

Heatizon custom panels are available for 120V, 208V, 240V, 277V, and 480V supply voltages — covering the full range of commercial and industrial electrical supply configurations. Panel breaker sizing is specified to the project’s circuit loads.

Heatizon’s Custom Panel Builds service designs and manufactures control panels for radiant heating systems to project-specific requirements. As a UL 508A certified panel shop, Heatizon engineers custom panels that integrate breakers, activation devices, monitoring functions, and BMS/BAS outputs — configured to the specific voltage, circuit count, enclosure type, and control requirements of each project. Every custom panel ships with complete wiring diagrams and is backed by full end-user support.

UL 508A is the standard for Industrial Control Panels — the governing certification for control panel enclosures that integrate components such as breakers, relays, indicators, and controllers into a listed panel assembly. A UL 508A certified panel shop is licensed to engineer, assemble, and list custom control panels to this standard. For commercial and industrial projects requiring a listed panel assembly — as required by most local building codes and electrical inspections — a UL 508A panel shop is a prerequisite for the work. Heatizon is a UL 508A certified panel shop, one of very few radiant heating manufacturers with this certification.